Addressable Fire Control Systems
- Home
- Automatic Fire Detection and Suppression Systems at AST Africa
- Addressable Fire Control Systems
Addressable Fire Control Systems

6500 Digital Addressable Loop Panel
The 6500 digital addressable fire control system is a high specification, feature rich, economical interactive digital addressable fire detection and alarm system ideally suited for small, medium and large sized buildings and complex multiple panel networked sites.

Addressable Interactive Sensors
AST offers a range of over 17 interactive 6000PLUS addressable high-performance sensors from low mass thermistor heat sensors to optical sensors that provide efficient reliable detection using the light scatter sensing principle with rapid response to a fire signal.
In addition, we provides carbon monoxide sensors that are used in conjunction with other detection principles such as optical and heat providing the ultimate in fast response to a fire signal while dismissing unwanted alarms. Sensor variants include integral programmable sounders, talking sounders and visual alarm devices.

Addressable Manual Callpoints
Designed and manufactured to the highest standards in an ISO9000 quality-controlled environment, the 6000 Series Manual Callpoint range is the ideal solution for fire alarm warning. The 6000/MCP indoor and outdoor 6000/MCP/WP utilise a special terminal block, where all initial installation cabling is terminated.

6000/SSR/LED Electronic Sounder Strobe
The 6000/SSR/LED comprises of a high output electronic sounder and high intensity flashing beacon range. Combining the two functions in one compact design, improves the aesthetic appearance and simplifies the installation of the device. This system can also come with a voice alarm function and is designed and assembled following current safety standards.

6000/SSR2 Electronic Sounder
The 6000/SSR2 addressable loop powered high output electronic sounder utilises a Piezo driver unit to enable high sound output and very low current consumption. With two base options and improved aesthetic appearance the 6000/SSR2 simplifies the installation of the device. This system can also come with a voice alarm function and is designed and assembled following current safety standards.

4 Channel Input/Output Interface
The AST’s 4 Channel Input/Output Interface is a auxiliary powered input / output device providing 2 local zones of conventional detectors, 2 monitored inputs, 2 local monitored alarm outputs and two volt free changeover contacts. The contacts may be used to connect to ancillary equipment.

2 Channel Input/Output Interface
The AST 2 Channel Input/Output Interface is a loop powered input / output device providing 2 monitored inputs and two volt free changeover contacts. The contacts may be used to connect to ancillary equipment.

2 Channel Loop Powered Zone Alarm Interface
The AST’s 2 way loop zone alarm interface is a loop powered input / output device providing 2 local zones of conventional detectors and 2 local monitored alarm outputs.

2 Channel Ancillary Powered Zone Alarm Interface
The AST 2 Channel Ancillary Powered Zone Alarm Interface is an auxiliary powered input / output device providing 2 local zones of conventional detectors and 2 local monitored alarm outputs.

6000 Monitored Input/Output Fire Alarm Interface
The 6000 series MICCO is a loop powered fault monitored input and a volt free clean contact output interface. An on-board isolator is provided which protects against loop short circuits on either the incoming or outgoing loop connections.
Under normal circumstances the input is terminated with an End of Line resistor. If the correct value of resistance is placed across the monitored input, the MICCO will activate the associated 6000 control panel within 3 seconds. The input is fully monitored for open and short circuit wiring faults.

Single Channel Loop Powered Zone Alarm Interface
The 6000 Single channel loop powered zone alarm interface which interfaces the 6000 series intelligent addressable loop to a zone of conventional devices and a conventional sounder circuit.
Most suitable to be used on small conventional fire detectors, it can be fully integrated with AST’s range of Intelligent addressable systems. The interface is powered using an external EN54 Part 4 power supply and can support up to 20 AST conventional (3000PLUS) detectors.

Single Channel Ancillary Powered Zone Alarm Interface
The AST 6000 Single Channel Ancillary Powered Zone Alarm Interface enables the 6000 series intelligent addressable loop to interface to a zone of conventional devices and a conventional sounder circuit.
This interface is suited for small conventional fire detection to be fully integrated with AST’s range of advanced technology addressable systems. It is powered using an external EN54 Part 4 power supply and can support up to 20 of AST’s conventional (3000PLUS) detectors.

Fire Beam Interface
The AST Fire Beam Interface is an unit which enables AST’s 6000 series of intelligent addressable loop systems to interface to conventional devices.
It is suited to interface ancillary conventional devices such as beam detectors and linear heat detection with our advanced addressable fire alarm systems. The fire beam interface is loop powered and does not require an external power supply.

6100 Digital Addressable Fire Control Panel
The 6100 control panel is equipped with a high capacity Algo-TecTM digital addressable data loop, with up to 192 addresses. In addition to the Algo-TecTM 6000PLUS sensors, interfaces and manual call points the loop can also support loop powered sounders, beacons and optical beam detectors.

Syncro AS Fire Control Panel
The Syncro AS analogue addressable fire control panel is the ideal panel for small and medium sized sites that require advanced fire sensing and evacuation options. AST offers this fire control panel in both its indoor and outdoor weather proof versions.